{"schema":"https://ver.cy/schemas/card/1.0.0","id":"vr.tr.bioelectricity","code":"thing-bioelectricity","url":"https://ver.cy/models/thing/bioelectricity/","name":"bioelectricity","alternateNames":[],"kind":"thing","status":"published","version":"0.2.0-wave.1","language":"en","classifiers":{"family":"Thing Registry","category":"Physical world and living systems","entryKind":"noun.phenomenon","plane":"PHY","domain":["PHY.FLW"],"industry":[],"navPath":"","tags":[],"facets":{"substance":"energy","origin":"natural","agency":"inert","mobility":"not-applicable","scale":"not-applicable","affordances":["observable"]}},"whatItIs":"Electrical phenomena in living organisms, arising from ion movements across cell membranes, including resting membrane potentials, nerve and muscle action potentials, the heart electrical activity and specialised electric organs in some fish.","purpose":"Let an agent explain bioelectricity by mechanism, measurement and examples, and separate evidence-based medical uses from unproven claims, without diagnosing.","scope":{"in":[],"out":[],"boundaries":[]},"distinguishingFeatures":["Generated by living cells","Driven by ion gradients","Measured with electrodes","Essential for nerves and heart"],"structure":{"bundles":[{"id":"mechanism","name":"Mechanism","description":"How it works.","layers":[{"id":"membrane","name":"Membrane","description":"Resting potential.","findings":[{"id":"membrane-finding","name":"Membrane","description":"Membrane potential.","questions":[{"text":"How do ion gradients create the resting membrane potential?","kind":"definition"},{"text":"What is a typical value?","kind":"measurement"}]}]},{"id":"action","name":"Action","description":"Action potentials.","findings":[{"id":"action-finding","name":"Action","description":"Action potentials.","questions":[{"text":"How does an action potential travel along a nerve?","kind":"definition"},{"text":"Which channels are involved?","kind":"definition"}]}]}]},{"id":"measurement","name":"Measurement","description":"Recording.","layers":[{"id":"clinical","name":"Clinical","description":"ECG and EEG.","findings":[{"id":"clinical-finding","name":"Clinical","description":"Clinical recordings.","questions":[{"text":"What do ECG and EEG measure, in general terms?","kind":"definition"},{"text":"Is the user asking to interpret their own recording?","kind":"boundary"}]}]},{"id":"research","name":"Research","description":"Lab methods.","findings":[{"id":"research-finding","name":"Research","description":"Research methods.","questions":[{"text":"How do researchers record from single cells?","kind":"definition"},{"text":"Which techniques are used?","kind":"provenance"}]}]}]},{"id":"nature","name":"Nature","description":"Examples.","layers":[{"id":"fish","name":"Fish","description":"Electric fish.","findings":[{"id":"fish-finding","name":"Fish","description":"Electric fish.","questions":[{"text":"How do electric eels and other fish generate discharges?","kind":"definition"},{"text":"What are they used for?","kind":"definition"}]}]},{"id":"plants","name":"Plants","description":"Plant signals.","findings":[{"id":"plants-finding","name":"Plants","description":"Plant electrical signals.","questions":[{"text":"What electrical signalling occurs in plants, such as the Venus flytrap?","kind":"provenance"},{"text":"How strong is the evidence?","kind":"boundary"}]}]}]},{"id":"claims","name":"Claims","description":"Evidence.","layers":[{"id":"products","name":"Products","description":"Health claims.","findings":[{"id":"products-finding","name":"Products","description":"Health product claims.","questions":[{"text":"Is there good evidence for this bioelectric health product?","kind":"boundary"},{"text":"Is it a regulated medical device?","kind":"provenance"}]}]},{"id":"emergency","name":"Emergency","description":"Heart emergencies.","findings":[{"id":"emergency-finding","name":"Emergency","description":"Heart emergencies.","questions":[{"text":"Has someone collapsed with a suspected cardiac arrest?","kind":"boundary"},{"text":"Should emergency services be called and a defibrillator found now?","kind":"action"}]}]}]}]},"agentConduct":{"may":["Explain membrane potentials, action potentials and electric organs from sourced physiology.","Point people to clinicians for interpretation of tests such as an ECG."],"mustNot":["Interpret a person's own ECG or other bioelectric recording as a diagnosis.","Recommend unproven bioelectric health products or devices.","Encourage home electrical stimulation outside a device's approved use.","Present speculative research as established treatment."],"requiresHuman":["Any decision about treatment based on a bioelectric measurement."]},"ethics":{"considerations":["False health claims about electricity and the body take money and delay real care.","Electrical stimulation can harm people with heart conditions or implants."],"affectedParties":["Patients","People with implanted devices","Buyers of health products"]},"owners":{"steward":"Nobody owns the phenomenon; clinicians answer for medical tests based on it.","roles":[],"masterSystems":[]},"relations":[{"target":"oewn-11438864-n","type":"parent","note":"registry parent class"},{"target":"electrical phenomenon","type":"related","note":"category"},{"target":"action potential","type":"related","note":"example"},{"target":"electrocardiography","type":"related","note":"method"},{"target":"electric fish","type":"related","note":"example"}],"interaction":{"identity":{"applicability":"required","items":["Vercy registry: vr.tr.bioelectricity","Open English WordNet: oewn-11449352-n"]},"properties":{"applicability":"required","items":["Potential difference:  V - Electrodes measure voltage between specified biological locations or between a recording location and a reference.","Electric current:  A - Electrophysiological instruments measure charge flow through a defined membrane region or biological conduction path.","Electrical conductivity:  S/m - Conductivity is derived from electrical measurements and sample geometry with tissue orientation, temperature and measurement frequency specified."]},"recognition":{"applicability":"required","items":["ECG, EEG and EMG traces","Electric organs in fish","Static electricity on skin is not bioelectricity","Not visible; recorded as traces such as ECG waves and neural spikes."]},"capabilities":{"applicability":"required","items":["explain membrane and action potentials","describe measurements such as ECG and EEG in general terms","describe electric fish","assess claims about bioelectric products with evidence"]},"hazards":{"applicability":"required","items":["Unproven bioelectric health products","Agents interpreting personal ECG results","Unsafe home electrical stimulation"]},"interfaces":{"applicability":"required","items":["Medical device rules for ECG and stimulators","Advertising rules on health claims"]},"context":{"applicability":"required","items":["Understanding nerves, muscles, the heart and development.","resting membrane potentials","action potentials","cardiac electrical activity","electric organs","bioelectric signals in development"]}},"sources":[{"title":"Open English WordNet 2024, synset oewn-11449352-n","url":"https://en-word.net/id/oewn-11449352-n","note":"sense and gloss of the concept"},{"title":"Wiktionary: bioelectricity","url":"https://en.wiktionary.org/wiki/bioelectricity","note":"word senses and usage"}],"openQuestions":["Should signal types be separate entries?","How should medical measurements be linked?","How should unproven claims be flagged?"],"resources":{"spec":"/models/things/publications/thing-bioelectricity/spec.json"},"provenance":{"origin":"thing registry research (pass 2)","builtFrom":["models/things/publications/thing-bioelectricity/spec.json"],"providers":["Claude"],"researchStatus":"unreviewed","generatedAt":"2026-09-11T12:19:31Z","builder":"tools/build_cards.py@1.0.0"},"completeness":{"sections":{"classifiers":"filled","whatItIs":"filled","purpose":"filled","distinguishingFeatures":"filled","structure":"filled","agentConduct":"filled","ethics":"filled","owners":"filled","relations":"filled","interaction.identity":"filled","interaction.properties":"filled","interaction.recognition":"filled","interaction.capabilities":"filled","interaction.hazards":"filled","interaction.interfaces":"filled","interaction.context":"filled","sources":"filled"},"notes":{"_gate":"Published through the thing publication gate 1.0 on 2026-10-07T12:16:27+00:00: completeness 1.00; sense: WordNet gloss; 2 live sources; review by codex: pass"},"score":1.0}}