{"schema":"https://ver.cy/schemas/card/1.0.0","id":"vr.tr.exposure-dose","code":"thing-exposure-dose","url":"https://ver.cy/models/thing/exposure-dose/","name":"exposure dose","alternateNames":[],"kind":"thing","status":"published","version":"0.2.0-wave.5","language":"en","classifiers":{"family":"Thing Registry","category":"Cross-cutting context","entryKind":"noun.quantity","plane":"XCT","domain":["XCT.QTY"],"industry":[],"navPath":"","tags":[],"facets":{"substance":"abstract","origin":"conceptual","agency":"inert","mobility":"not-applicable","scale":"not-applicable","affordances":["observable"]}},"whatItIs":"Exposure (historically 'exposure dose'), symbol X: the charge of ions of one sign produced in dry air per unit mass, X = dQ/dm, when all electrons and positrons liberated by X-ray or gamma photons are completely stopped in air, excluding ionisation from their bremsstrahlung; in C/kg, with the old unit roentgen equal to exactly 2.58 x 10^-4 C/kg.","purpose":"Let an agent convert exposure units, tell exposure apart from absorbed and equivalent dose, and route radiation safety questions to radiation protection experts.","scope":{"in":[],"out":[],"boundaries":[]},"distinguishingFeatures":["Defined only for X and gamma radiation in dry air; 'exposure dose' is historical wording.","Absorbed dose (gray) is energy per mass in any material; equivalent dose (sievert) weights it for biological effect; converting needs energy, material and conditions, not just a unit factor.","Largely replaced by air kerma in modern practice."],"structure":{"bundles":[{"id":"definition","name":"Definition","description":"What exposure measures.","layers":[{"id":"quantity","name":"Quantity","description":"Charge per mass of air.","findings":[{"id":"definition","name":"Definition","description":"Scope and conditions.","questions":[{"text":"Does the figure concern X or gamma rays in air?","kind":"boundary"},{"text":"Is it exposure or exposure rate?","kind":"boundary"}]}]},{"id":"units","name":"Units","description":"C/kg and roentgen.","findings":[{"id":"unit-conversion","name":"Unit conversion","description":"Exact factor.","questions":[{"text":"What is the value in C/kg?","kind":"measurement"},{"text":"Is the old unit roentgen used?","kind":"provenance"}]}]}]},{"id":"related-quantities","name":"Related quantities","description":"Dose quantities.","layers":[{"id":"air-kerma","name":"Air kerma","description":"Modern replacement.","findings":[{"id":"air-kerma","name":"Air kerma","description":"Relation to exposure.","questions":[{"text":"Should air kerma be used instead?","kind":"boundary"},{"text":"How do the values relate?","kind":"measurement"}]}]},{"id":"absorbed-and-equivalent-dose","name":"Absorbed and equivalent dose","description":"Gray and sievert.","findings":[{"id":"dose-quantities","name":"Dose quantities","description":"Which quantity is needed.","questions":[{"text":"Is absorbed or equivalent dose what is needed?","kind":"boundary"},{"text":"Who can convert it properly?","kind":"action"}]}]}]},{"id":"measurement","name":"Measurement","description":"Instruments.","layers":[{"id":"instruments","name":"Instruments","description":"Ionisation chambers and survey meters.","findings":[{"id":"instrument","name":"Instrument","description":"Type and calibration.","questions":[{"text":"Which instrument measured it?","kind":"provenance"},{"text":"When was it calibrated?","kind":"provenance"}]}]},{"id":"uncertainty","name":"Uncertainty","description":"Accuracy.","findings":[{"id":"uncertainty","name":"Uncertainty","description":"Measurement uncertainty.","questions":[{"text":"What is the uncertainty?","kind":"measurement"},{"text":"Which energy range was it calibrated for?","kind":"boundary"}]}]}]},{"id":"safety","name":"Safety","description":"Radiation protection.","layers":[{"id":"protection","name":"Protection","description":"Limits and principles.","findings":[{"id":"protection-rules","name":"Protection rules","description":"Applicable rules.","questions":[{"text":"Which radiation protection rules apply?","kind":"provenance"},{"text":"Who is the radiation protection officer?","kind":"action"}]}]},{"id":"incidents","name":"Incidents","description":"Overexposure.","findings":[{"id":"incident","name":"Incident","description":"Report and response.","questions":[{"text":"Has an overexposure been reported?","kind":"provenance"},{"text":"Which authority must be informed?","kind":"action"}]}]}]}]},"agentConduct":{"may":["convert units and explain quantities"],"mustNot":["make radiation safety or medical exposure decisions","advise on handling radioactive sources"],"requiresHuman":["any radiation protection decision, which belongs to qualified radiation protection experts"]},"ethics":{"considerations":["radiation safety of workers and public"],"affectedParties":["workers","patients","the public"]},"owners":{"steward":"nobody; a quantity defined by the ICRU","roles":[],"masterSystems":["ICRU reports"]},"relations":[{"target":"oewn-00033914-n","type":"parent","note":"registry parent class"},{"target":"radiation quantity","type":"related","note":"dosimetric quantity"},{"target":"exposure rate","type":"related","note":"per unit time"},{"target":"absorbed dose","type":"related","note":"measured in gray"},{"target":"air kerma","type":"related","note":"in modern practice"}],"interaction":{"identity":{"applicability":"required","items":["Vercy registry: vr.tr.exposure-dose","Open English WordNet: oewn-92466752-n","unit: C/kg; R 1 R = 2.58e-4 C/kg exactly"]},"properties":{"applicability":"not-applicable","items":["1 roentgen: 2.58e-4 C/kg - exact by definition"]},"recognition":{"applicability":"optional","items":["Stated in roentgen (R) or C/kg, often as a rate per hour"]},"capabilities":{"applicability":"required","items":["convert between roentgen and C/kg exactly","distinguish exposure, air kerma, absorbed dose and equivalent dose","explain why exposure applies only to photons in air"]},"hazards":{"applicability":"required","items":["Confusing exposure with dose in safety assessments","Radiation overexposure"]},"interfaces":{"applicability":"required","items":["ICRU Report 85a, Fundamental Quantities and Units for Ionizing Radiation (Revised), 2011","SI Brochure (BIPM) on radiation units"]},"context":{"applicability":"required","items":["Characterising X-ray and gamma radiation fields, historically for calibrating instruments and radiation protection.","exposure X (C/kg)"]}},"sources":[{"title":"ICRU Report 85a: Fundamental Quantities and Units for Ionizing Radiation","url":"https://www.aapm.org/pubs/protected_files/ICRU/ICRU_Report_85_Fundamental_Quantities_and_Units_for_Ionizing_Radiation_AAPM.pdf","note":"definition of exposure"},{"title":"Radiation Quantities and Units: ICRU Report 10a","url":"https://nvlpubs.nist.gov/nistpubs/Legacy/hb/nbshandbook84.pdf","note":"historical exposure dose terminology"},{"title":"SI Brochure, Appendix 1: Derived Units","url":"https://www.bipm.org/en/publications/si-brochure/annex-1/derived-units","note":"units"},{"title":"Irradiation of Passive Dosimeters","url":"https://www.nist.gov/system/files/documents/2023/05/04/Procedure05v600.pdf","note":"calibration practice"}],"openQuestions":["Should air kerma have its own entry?"],"resources":{"spec":"/models/things/publications/thing-exposure-dose/spec.json"},"provenance":{"origin":"thing registry research (pass 2)","builtFrom":["models/things/publications/thing-exposure-dose/spec.json"],"providers":["Claude"],"researchStatus":"unreviewed","generatedAt":"2026-10-21T19:46:56Z","builder":"tools/build_cards.py@1.0.0"},"completeness":{"sections":{"classifiers":"filled","whatItIs":"filled","purpose":"filled","distinguishingFeatures":"filled","structure":"filled","agentConduct":"filled","ethics":"filled","owners":"filled","relations":"filled","interaction.identity":"filled","interaction.properties":"not-applicable","interaction.recognition":"filled","interaction.capabilities":"filled","interaction.hazards":"filled","interaction.interfaces":"filled","interaction.context":"filled","sources":"filled"},"notes":{"_gate":"Published through the thing publication gate 1.0 on 2026-10-21T19:51:01+00:00: completeness 1.00; sense: WordNet gloss; 4 live sources; review by codex: pass","interaction.properties":"Plane XCT: no invented physical properties."},"score":1.0}}