{
  "vercy": "1.0-draft",
  "publication": {
    "status": "research-draft",
    "adjudicationStatus": "unreviewed",
    "publishableCanonical": false,
    "generatedAt": "2026-10-21T19:46:56Z",
    "providers": [
      "Claude"
    ],
    "breadth": "researched by Claude against the sources listed below",
    "pass": 2,
    "wave": 5,
    "engine": "claude",
    "gate": {
      "passed": true,
      "version": "1.0",
      "at": "2026-10-21T19:51:01+00:00",
      "evidence": [
        "completeness 1.00",
        "sense: WordNet gloss",
        "4 live sources",
        "review by codex: pass"
      ]
    }
  },
  "metaModel": {
    "id": "THING-EXPOSURE-DOSE",
    "registryId": "vr.tr.exposure-dose",
    "name": "exposure dose",
    "version": "0.2.0-wave.5",
    "entryKind": "thing",
    "family": "Thing Registry",
    "domain": [
      "XCT.QTY"
    ],
    "status": "research-draft"
  },
  "canonicalUrl": "https://ver.cy/models/thing/exposure-dose/",
  "model": {
    "registry_id": "vr.tr.exposure-dose",
    "name": "exposure dose",
    "purpose": "Let an agent convert exposure units, tell exposure apart from absorbed and equivalent dose, and route radiation safety questions to radiation protection experts.",
    "definition": "Exposure (historically 'exposure dose'), symbol X: the charge of ions of one sign produced in dry air per unit mass, X = dQ/dm, when all electrons and positrons liberated by X-ray or gamma photons are completely stopped in air, excluding ionisation from their bremsstrahlung; in C/kg, with the old unit roentgen equal to exactly 2.58 x 10^-4 C/kg.",
    "what_it_is_for": "Characterising X-ray and gamma radiation fields, historically for calibrating instruments and radiation protection.",
    "affordances": [
      "convert between roentgen and C/kg exactly",
      "distinguish exposure, air kerma, absorbed dose and equivalent dose",
      "explain why exposure applies only to photons in air"
    ],
    "distinguishing_features": [
      "Defined only for X and gamma radiation in dry air; 'exposure dose' is historical wording.",
      "Absorbed dose (gray) is energy per mass in any material; equivalent dose (sievert) weights it for biological effect; converting needs energy, material and conditions, not just a unit factor.",
      "Largely replaced by air kerma in modern practice."
    ],
    "appearance": null,
    "visual_identification": [
      "Stated in roentgen (R) or C/kg, often as a rate per hour"
    ],
    "physical_properties": [
      {
        "quantity": "1 roentgen",
        "typical_range": "2.58e-4",
        "unit": "C/kg",
        "note": "exact by definition"
      }
    ],
    "families_and_kinds": [
      "exposure X (C/kg)"
    ],
    "related_models": [
      {
        "relation": "is a kind of",
        "target": "radiation quantity",
        "why": "dosimetric quantity"
      },
      {
        "relation": "has derivative",
        "target": "exposure rate",
        "why": "per unit time"
      },
      {
        "relation": "is confused with",
        "target": "absorbed dose",
        "why": "measured in gray"
      },
      {
        "relation": "is replaced by",
        "target": "air kerma",
        "why": "in modern practice"
      }
    ],
    "identifiers": [
      {
        "scheme": "unit",
        "value_or_pattern": "C/kg; R",
        "note": "1 R = 2.58e-4 C/kg exactly"
      }
    ],
    "standards_and_regulation": [
      "ICRU Report 85a, Fundamental Quantities and Units for Ionizing Radiation (Revised), 2011",
      "SI Brochure (BIPM) on radiation units"
    ],
    "failure_modes_and_hazards": [
      "Confusing exposure with dose in safety assessments",
      "Radiation overexposure"
    ],
    "agent_conduct": {
      "may": [
        "convert units and explain quantities"
      ],
      "must_not": [
        "make radiation safety or medical exposure decisions",
        "advise on handling radioactive sources"
      ],
      "requires_human": [
        "any radiation protection decision, which belongs to qualified radiation protection experts"
      ]
    },
    "ethics": {
      "considerations": [
        "radiation safety of workers and public"
      ],
      "affected_parties": [
        "workers",
        "patients",
        "the public"
      ]
    },
    "owners": {
      "steward": "nobody; a quantity defined by the ICRU",
      "master_systems": [
        "ICRU reports"
      ]
    },
    "facets_not_applicable": {},
    "in_scope": [],
    "out_of_scope": [],
    "characteristics": []
  },
  "sources": [
    {
      "id": "SRC-001",
      "title": "ICRU Report 85a: Fundamental Quantities and Units for Ionizing Radiation",
      "publisher": "ICRU (hosted by AAPM)",
      "url": "https://www.aapm.org/pubs/protected_files/ICRU/ICRU_Report_85_Fundamental_Quantities_and_Units_for_Ionizing_Radiation_AAPM.pdf",
      "what_it_supports": "definition of exposure",
      "url_status": "live"
    },
    {
      "id": "SRC-002",
      "title": "Radiation Quantities and Units: ICRU Report 10a",
      "publisher": "US National Bureau of Standards",
      "url": "https://nvlpubs.nist.gov/nistpubs/Legacy/hb/nbshandbook84.pdf",
      "what_it_supports": "historical exposure dose terminology",
      "url_status": "live"
    },
    {
      "id": "SRC-003",
      "title": "SI Brochure, Appendix 1: Derived Units",
      "publisher": "BIPM",
      "url": "https://www.bipm.org/en/publications/si-brochure/annex-1/derived-units",
      "what_it_supports": "units",
      "url_status": "live"
    },
    {
      "id": "SRC-004",
      "title": "Irradiation of Passive Dosimeters",
      "publisher": "NIST",
      "url": "https://www.nist.gov/system/files/documents/2023/05/04/Procedure05v600.pdf",
      "what_it_supports": "calibration practice",
      "url_status": "live"
    }
  ],
  "structure": {
    "bundles": [
      {
        "id": "definition",
        "name": "Definition",
        "description": "What exposure measures.",
        "rationale": "Exposure is narrow and easily confused.",
        "layers": [
          {
            "id": "quantity",
            "name": "Quantity",
            "description": "Charge per mass of air.",
            "findings": [
              {
                "id": "definition",
                "name": "Definition",
                "description": "Scope and conditions.",
                "questions": [
                  {
                    "text": "Does the figure concern X or gamma rays in air?",
                    "kind": "boundary"
                  },
                  {
                    "text": "Is it exposure or exposure rate?",
                    "kind": "boundary"
                  }
                ]
              }
            ]
          },
          {
            "id": "units",
            "name": "Units",
            "description": "C/kg and roentgen.",
            "findings": [
              {
                "id": "unit-conversion",
                "name": "Unit conversion",
                "description": "Exact factor.",
                "questions": [
                  {
                    "text": "What is the value in C/kg?",
                    "kind": "measurement"
                  },
                  {
                    "text": "Is the old unit roentgen used?",
                    "kind": "provenance"
                  }
                ]
              }
            ]
          }
        ]
      },
      {
        "id": "related-quantities",
        "name": "Related quantities",
        "description": "Dose quantities.",
        "rationale": "Safety uses dose, not exposure.",
        "layers": [
          {
            "id": "air-kerma",
            "name": "Air kerma",
            "description": "Modern replacement.",
            "findings": [
              {
                "id": "air-kerma",
                "name": "Air kerma",
                "description": "Relation to exposure.",
                "questions": [
                  {
                    "text": "Should air kerma be used instead?",
                    "kind": "boundary"
                  },
                  {
                    "text": "How do the values relate?",
                    "kind": "measurement"
                  }
                ]
              }
            ]
          },
          {
            "id": "absorbed-and-equivalent-dose",
            "name": "Absorbed and equivalent dose",
            "description": "Gray and sievert.",
            "findings": [
              {
                "id": "dose-quantities",
                "name": "Dose quantities",
                "description": "Which quantity is needed.",
                "questions": [
                  {
                    "text": "Is absorbed or equivalent dose what is needed?",
                    "kind": "boundary"
                  },
                  {
                    "text": "Who can convert it properly?",
                    "kind": "action"
                  }
                ]
              }
            ]
          }
        ]
      },
      {
        "id": "measurement",
        "name": "Measurement",
        "description": "Instruments.",
        "rationale": "Calibration ties values to standards.",
        "layers": [
          {
            "id": "instruments",
            "name": "Instruments",
            "description": "Ionisation chambers and survey meters.",
            "findings": [
              {
                "id": "instrument",
                "name": "Instrument",
                "description": "Type and calibration.",
                "questions": [
                  {
                    "text": "Which instrument measured it?",
                    "kind": "provenance"
                  },
                  {
                    "text": "When was it calibrated?",
                    "kind": "provenance"
                  }
                ]
              }
            ]
          },
          {
            "id": "uncertainty",
            "name": "Uncertainty",
            "description": "Accuracy.",
            "findings": [
              {
                "id": "uncertainty",
                "name": "Uncertainty",
                "description": "Measurement uncertainty.",
                "questions": [
                  {
                    "text": "What is the uncertainty?",
                    "kind": "measurement"
                  },
                  {
                    "text": "Which energy range was it calibrated for?",
                    "kind": "boundary"
                  }
                ]
              }
            ]
          }
        ]
      },
      {
        "id": "safety",
        "name": "Safety",
        "description": "Radiation protection.",
        "rationale": "Agents route safety to experts.",
        "layers": [
          {
            "id": "protection",
            "name": "Protection",
            "description": "Limits and principles.",
            "findings": [
              {
                "id": "protection-rules",
                "name": "Protection rules",
                "description": "Applicable rules.",
                "questions": [
                  {
                    "text": "Which radiation protection rules apply?",
                    "kind": "provenance"
                  },
                  {
                    "text": "Who is the radiation protection officer?",
                    "kind": "action"
                  }
                ]
              }
            ]
          },
          {
            "id": "incidents",
            "name": "Incidents",
            "description": "Overexposure.",
            "findings": [
              {
                "id": "incident",
                "name": "Incident",
                "description": "Report and response.",
                "questions": [
                  {
                    "text": "Has an overexposure been reported?",
                    "kind": "provenance"
                  },
                  {
                    "text": "Which authority must be informed?",
                    "kind": "action"
                  }
                ]
              }
            ]
          }
        ]
      }
    ]
  },
  "openQuestions": [
    "Should air kerma have its own entry?"
  ],
  "statistics": {
    "bundles": 4,
    "layers": 8,
    "findings": 8,
    "questions": 16
  }
}
